Light environment

Goal

lightsim2grid.lightEnv.LightEnv is a (very) limited grid2op environment written entirely in C++: the loop reset / step / protections / cooldowns / observation runs without going back to python, and without grid2op’s bookkeeping around it. It is meant for the workloads where the environment itself is the bottleneck: training an agent that only acts on the topology, or a search (tree search, beam search, …) that evaluates many candidate actions one step ahead.

It is not a replacement of grid2op. It models one thing – a grid replaying a time series of injections, on which an agent changes the topology – and it follows grid2op’s semantics for that one thing, so an agent can be trained or searched on the light environment and run on grid2op afterwards. See What it does not model for what it leaves out.

On l2rpn_case14_sandbox a step is 25 to 50 times faster than a grid2op step with lightsim2grid.LightSimBackend, and evaluating a candidate action is about 20 times faster than obs.simulate (see Benchmark).

Note

The light environment is new and its interface may still change. It is also usable from C++ with no python at all: it is header-only, in src/core/light_env/ (installed with the core library, see Using lightsim2grid as a C++ library).

Quick start

The easiest way to build one is from a grid2op environment using lightsim2grid.LightSimBackend: the grid of its backend is the initial state of every episode, and the thermal limits, the protections and the cooldowns are taken from its parameters. This is the setup used by the benchmark (benchmarks/light_env.py):

import numpy as np
import grid2op
from lightsim2grid import LightSimBackend
from lightsim2grid.lightEnv import LightEnv, Protections

env = grid2op.make("l2rpn_case14_sandbox", backend=LightSimBackend())
env.reset()

# the grid the episode starts from (the topology is restored at every reset)
light_env = LightEnv(env.backend._grid)

# the injections: one row per step, one column per element, NaN meaning "unchanged"
# (a quantity left out, or None, keeps the value of the initial grid)
data = env.chronics_handler.real_data.data
light_env.assign_time_series(
    load_p=data.load_p,
    load_q=data.load_q,
    gen_p=data.prod_p,
    gen_v=data.prod_v / env.backend.prod_pu_to_kv,  # in pu, not kV
)

# the protections: thermal limits in kA (grid2op uses A), on both sides of each line
th_lim_ka = env.get_thermal_limit() * 1e-3
protections = Protections()
protections.set_thermal_limit_or(th_lim_ka)
protections.set_thermal_limit_ex(th_lim_ka * env.backend.lines_or_pu_to_kv / env.backend.lines_ex_pu_to_kv)
# or, for grid2op's rho (origin side only): protections.set_thermal_limit_ex(np.full(env.n_line, np.nan))
protections.set_max_line_time_step_overflow(
    np.full(env.n_line, env.parameters.NB_TIMESTEP_OVERFLOW_ALLOWED, dtype=np.int32))
light_env.protections = protections

# the cooldowns (grid2op parameters of the same name)
light_env.nb_timestep_cooldown_sub = env.parameters.NB_TIMESTEP_COOLDOWN_SUB
light_env.nb_timestep_cooldown_line = env.parameters.NB_TIMESTEP_COOLDOWN_LINE
light_env.nb_timestep_reconnection = env.parameters.NB_TIMESTEP_RECONNECTION

# the actions the agent can take: step(i) plays actions[i]
actions = [env.action_space()] + list(env.action_space.get_all_unitary_topologies_set(env.action_space))
light_env.init_actions(actions)

obs, info = light_env.reset()
done = False
while not done:
    act_id = 0  # your agent here
    obs, reward, done, truncated, info = light_env.step(act_id)

Setting it up

The grid. LightEnv(grid) takes an lightsim2grid.network.LSGrid and copies it: this copy is the state every episode starts from (reset restores its topology). A grid loaded by lightsim2grid.LightSimBackend also carries the position of every element in grid2op’s topology vector, which obs.topo_vect needs; a grid loaded directly (eg with init_from_pandapower) works, but has no topo_vect.

The time series (assign_time_series). Nine matrices, one row per step, one column per element: load_p, load_q, gen_p (MW / MVAr), gen_v (pu), storage_p, shunt_p, shunt_q, sgen_p, sgen_q. A NaN leaves the value of the grid unchanged, and a matrix left out (None, the default) is all NaN: that quantity keeps the value of the initial grid, eg gen_v=None for an environment without a prod_v time series. At least one matrix is needed. They must all have the same number of rows, which becomes max_step; the sizes are checked at the next reset. For now only load_p, load_q, gen_p and gen_v are applied, the other five are only checked.

The protections (lightsim2grid.lightEnv.Protections). The thermal limits, in kA, on both sides of every line (grid2op numbering: powerlines then transformers, the “or” side of a transformer being its hv side), and for each line the number of steps it can stay in overflow. rho is the max over both sides of current / thermal limit; a NaN (or infinite) limit leaves its side out, and a line with no limit on either side has a rho of 0 and never trips. grid2op only looks at the origin side (rho = a_or / limit): a NaN on every extremity side reproduces it, whereas both sides read higher on lines whose current differs a lot from one end to the other (high charging), and can trip lines grid2op keeps. A line whose overflow counter exceeds that number is disconnected, the powerflow is run again, and so on until no more line trips (a cascade, within one step). This is grid2op’s “soft” overflow protection (NB_TIMESTEP_OVERFLOW_ALLOWED).

The cooldowns. nb_timestep_cooldown_sub, nb_timestep_cooldown_line and nb_timestep_reconnection behave as the grid2op parameters of the same name: after an action touches a substation (resp. changes the status of a line) that substation (resp. line) cannot be acted on for that many steps, and a line disconnected by the protections cannot be reconnected before nb_timestep_reconnection steps.

The actions (init_actions). A list of grid2op actions or of lightsim2grid.lightEnv.TopoAction, mixing both is fine. Only set_bus and set_line_status are modelled; a grid2op action using anything else that affects the grid (change_bus, redispatch, curtail, storage…) is refused. Every action is checked against the initial grid (the element exists, the busbar exists, no contradiction) and an invalid one raises a ValueError naming it; nothing is registered in that case. Without any action registered, step(0) (do nothing) is the only valid call.

A lightsim2grid.lightEnv.TopoAction can also be built by hand, with grid2op semantics:

from lightsim2grid.lightEnv import TopoAction, ElementType

act = TopoAction()
act.add_element(ElementType.load, 0, 2)      # set_bus: load 0 on busbar 2 of its substation
act.add_element(ElementType.line_or, 2, 2)   # origin side of line 2 on busbar 2
act.set_line_status(3, -1)                   # set_line_status: disconnect line 3

Playing an episode

reset() restores the initial topology, the overflow counters and the cooldowns, applies the first row of the time series, runs a powerflow and returns (obs, info). It must be called before the first step, and again after assign_time_series or a change of the protections. If that powerflow diverges there is no episode to play: reset raises a RuntimeError and the env cannot be stepped.

step(act_id) returns (obs, reward, done, truncated, info):

  • the action act_id is played, unless it touches a substation or a line still in cooldown: it is then replaced by “do nothing” and info["is_illegal"] is "true";

  • the next row of the time series is applied, and the powerflow is run with the protections (the cascade described above);

  • reward is the fraction of the episode survived so far, current_step / max_step;

  • done is True at the end of the time series (info["success"] == "true", reward 1) or when the powerflow diverges (info["failure"] == "true", reward 0, truncated is True). info["survival_time"] is then the fraction of the episode survived.

The values in info are strings.

The observation

obs is a lightsim2grid.lightEnv.LightEnvObservation, a view on the state of the environment: every attribute is a read-only numpy array on the environment’s memory, nothing is copied. reset and every step return the same object, whose values follow the environment. Use np.array(obs.p_or) to keep a snapshot.

attribute

meaning

rho

max over both sides of current / limit, per line (see above)

p_or, q_or, a_or

flows at the origin side (MW, MVAr, kA), per line

p_ex, q_ex, a_ex

flows at the extremity side (MW, MVAr, kA), per line

load_p, gen_p

active power of the loads / generators (MW)

topo_vect

grid2op topology vector (local busbar, -1 if disconnected)

time_before_cooldown_line

steps before the status of each line can change again

time_before_cooldown_sub

steps before each substation can be acted on again

current_step

step of the environment (0 at reset)

Lines follow grid2op numbering. Currents are in kA, where grid2op uses A.

A view is valid until the next reset, or a step ending the episode by a divergence (the grid then drops its results); once done is True the values are not meaningful.

What it does not model

Compared with a grid2op environment:

  • the only actions are set_bus and set_line_status: no change_bus / change_line_status, no redispatching, curtailment, storage, or setpoint change;

  • only load_p, load_q, gen_p and gen_v are replayed: storage units, shunts and static generators keep the values of the initial grid;

  • no maintenance, no opponent, no forecasts, no alarms / alerts;

  • no limit on the number of substations or lines an action touches (MAX_SUB_CHANGED, MAX_LINE_STATUS_CHANGED), only the cooldowns;

  • only the “soft” overflow protection: no instantaneous disconnection above HARD_OVERFLOW_THRESHOLD, and a line is in overflow when rho >= 1 (grid2op: above SOFT_OVERFLOW_THRESHOLD, 1 by default);

  • a single reward, the fraction of the episode survived;

  • every powerflow starts from a flat DC initialisation, rather than from the previous state.

Within these limits it follows grid2op step by step: lightsim2grid/tests/test_LightEnv.py plays the same actions on both and compares the flows, the topology and the cooldowns at every step.

Benchmark

benchmarks/light_env.py plays the same chronics of l2rpn_case14_sandbox on a grid2op environment with lightsim2grid.LightSimBackend and on a light environment built as in the quick start, with the same thermal limits and protections. Its thermal limits are on the origin side only, as grid2op’s rho (--rho_both_sides limits both sides). grid2op’s HARD_OVERFLOW_THRESHOLD is raised out of reach, so both sides model the same thing (see above). Three workloads:

  • do nothing: env.step(do_nothing) vs light_env.step(0);

  • topology: every 10 steps a random unitary set_bus action (the same sequence of actions on both sides), do nothing otherwise. Such an agent ends its episode quickly, so 50 episodes are played;

  • lookahead: at every step, 10 candidate actions are evaluated one step ahead (obs.simulate(act) vs light_env.copy().step(act_id)), then the episode goes on with do nothing. Only the evaluation is timed.

To run it (cd into the benchmarks folder, grid2op installed):

python light_env.py            # the test chronics shipped with grid2op (3 x 575 steps)
python light_env.py --no_test  # the full dataset, downloaded by grid2op

The results below were obtained on the test chronics, on a shared cloud machine (Intel Xeon @ 2.10GHz, python 3.11, grid2op 1.12.5, lightsim2grid 1.0.1rc0 with KLU, compiled without -O3 / -march=native). Timings vary by up to a factor 2 from one run to the next on such a machine; the ratio between the two columns is what matters.

“ms / step (in env)” is the time the environment accounts for itself (grid2op env._time_step, the light env step_time) and “powerflow” the time spent in the powerflows, protections included (grid2op env._time_powerflow, the light env protections.powerflow_time, which also counts the powerflow of reset). Both sides play the same number of steps and end the same episodes: they agree on the physics.

Do nothing:

steps

game over

steps / s

ms / step

ms / step (in env)

ms / step (powerflow)

grid2op + LightSimBackend

1725

0

1153

0.868

0.790

0.187

LightEnv

1725

0

54503

0.018

0.017

0.015

Topology (a random unitary set_bus action every 10 steps, 50 episodes):

steps

game over

steps / s

ms / step

ms / step (in env)

ms / step (powerflow)

grid2op + LightSimBackend

1246

50

1294

0.773

0.706

0.176

LightEnv

1246

50

31620

0.032

0.029

0.030

Lookahead (10 candidate actions per step, one step ahead):

steps

game over

steps / s

ms / step

grid2op obs.simulate

17220

0

634

1.577

LightEnv copy + step

17220

0

12160

0.082

In short, over three runs: a step is 25 to 50 times faster, and a one-step lookahead about 20 times faster. Most of a grid2op step is spent outside the powerflow (compare the last two columns): applying the action, the rules, building the observation. The light environment spends almost all of its time in the powerflow, and the python binding adds little per step (the gap between “ms / step” and “ms / step (in env)”). A step with a topological change is slower than a do nothing one, as the admittance matrix has to be rebuilt, and the lookahead is dominated by the first step of each copy, which starts from a cold solver (see Copying: lookahead and search).

Detailed usage

Python side of the light environment: a LightEnv whose actions can be given as grid2op actions.

Classes:

ElementType

This enum controls the topology action in the light environment of lightsim2grid

LightEnv

The light environment, see the c++ documentation.

LightEnvObservation

Observation of a LightEnv: a read-only view on the current state of its environment, nothing is copied.

Protections

Limited protection used for the light environment

TopoAction

Limited topological action used for the light environment, with grid2op semantics: add_element is grid2op set_bus (local busbar id: -1 disconnect, 0 nothing, 1..n_busbar_per_sub), set_line_status is grid2op set_line_status (-1, 0, +1).

Functions:

topo_action_from_grid2op(action)

Convert a grid2op action into a (not yet checked) TopoAction.

class lightsim2grid.lightEnv.ElementType

This enum controls the topology action in the light environment of lightsim2grid

Members:

load : denotes a load

gen : denotes a gen

line_or : denotes a line (origin side)

line_ex : denotes a line (ext side)

storage : denotes a storage unit

trafo_hv : denotes a trafo (hv side)

trafo_lv : denotes a trafo (lv side)

shunt : denotes a shunt

static_gen : denotes a static generator

dc_line_or : denotes a dc powerline (or side)

dc_line_ex : denotes a dc powerline (ex side)

Attributes:

name

property name
class lightsim2grid.lightEnv.LightEnv[source]

The light environment, see the c++ documentation. On top of it, LightEnv.init_actions() also accepts grid2op actions.

It can be copied (env.copy(), copy.copy(env), copy.deepcopy(env) or LightEnv(env), all the same): the copy is an independent env at the same point of the same episode, with its own observation. The initial grid, the time series and the registered actions, which do not change during an episode, are shared read-only.

Methods:

assign_time_series([load_p, load_q, gen_p, ...])

Give the injections replayed by the episode: one matrix per quantity, one row per step and one column per element (MW, MVAr, gen_v in pu).

copy()

An independent copy of this env, at the same step (see the class documentation).

init_actions(actions)

Register the actions the agent can take: step(i) plays actions[i].

assign_time_series(load_p: ndarray | None = None, load_q: ndarray | None = None, gen_p: ndarray | None = None, gen_v: ndarray | None = None, storage_p: ndarray | None = None, shunt_p: ndarray | None = None, shunt_q: ndarray | None = None, sgen_p: ndarray | None = None, sgen_q: ndarray | None = None) → None[source]

Give the injections replayed by the episode: one matrix per quantity, one row per step and one column per element (MW, MVAr, gen_v in pu).

A NaN leaves the value of the grid unchanged, and a matrix left to None is a matrix of NaN: that quantity keeps the value of the initial grid for the whole episode (eg gen_v=None for an environment without a prod_v time series). At least one matrix must be given, the number of steps is taken from it.

copy() → LightEnv[source]

An independent copy of this env, at the same step (see the class documentation).

init_actions(actions: Iterable) → None[source]

Register the actions the agent can take: step(i) plays actions[i].

actions is a list of grid2op actions (set_bus and set_line_status only, see topo_action_from_grid2op()) or of TopoAction, mixing both is fine. Every action is checked against the initial grid: an element that does not exist, a busbar that does not exist (eg -2, or 3 on a grid with 2 busbars per substation), an unsupported modification or a contradiction raises a ValueError naming the action, and nothing is registered.

class lightsim2grid.lightEnv.LightEnvObservation

Observation of a LightEnv: a read-only view on the current state of its environment, nothing is copied. Every attribute is a read-only numpy array on the environment’s memory, so it follows the environment as it steps (it is not a snapshot: use np.array(obs.p_or) to keep one). An array is valid until the next reset of the environment or a step ending the episode by a divergence; once done is True the values are not meaningful. Lines use grid2op numbering (powerlines then transformers, ‘or’ being a transformer’s hv side), powers are in MW / MVAr, currents in kA (like the thermal limits of Protections).

Attributes:

a_ex

Current flow (kA) at the extremity side of each line

a_or

Current flow (kA) at the origin side of each line

current_step

Step of the environment (0 at reset)

gen_p

Active power (MW) produced by each generator

load_p

Active power (MW) consumed by each load

p_ex

Active power flow (MW) at the extremity side of each line

p_or

Active power flow (MW) at the origin side of each line

q_ex

Reactive power flow (MVAr) at the extremity side of each line

q_or

Reactive power flow (MVAr) at the origin side of each line

rho

For each line, the max over its two sides of current / thermal limit (a side whose limit is NaN or infinite left out, 0 if both are)

time_before_cooldown_line

For each line, number of steps before its status can be changed again

time_before_cooldown_sub

For each substation, number of steps before it can be acted on again

topo_vect

the local busbar (1..n_busbar_per_sub, -1 if disconnected) of every element, at its grid2op position.

property a_ex

Current flow (kA) at the extremity side of each line

property a_or

Current flow (kA) at the origin side of each line

property current_step

Step of the environment (0 at reset)

property gen_p

Active power (MW) produced by each generator

property load_p

Active power (MW) consumed by each load

property p_ex

Active power flow (MW) at the extremity side of each line

property p_or

Active power flow (MW) at the origin side of each line

property q_ex

Reactive power flow (MVAr) at the extremity side of each line

property q_or

Reactive power flow (MVAr) at the origin side of each line

property rho

For each line, the max over its two sides of current / thermal limit (a side whose limit is NaN or infinite left out, 0 if both are)

property time_before_cooldown_line

For each line, number of steps before its status can be changed again

property time_before_cooldown_sub

For each substation, number of steps before it can be acted on again

property topo_vect

the local busbar (1..n_busbar_per_sub, -1 if disconnected) of every element, at its grid2op position. Raises if the grid carries no position in the topology vector (they are set by LightSimBackend).

Type:

grid2op topology vector

class lightsim2grid.lightEnv.Protections

Limited protection used for the light environment

Methods:

get_max_line_time_step_overflow(self)

For each line, the number of steps it can stay in overflow: it is disconnected once its overflow counter exceeds this value (grid2op NB_TIMESTEP_OVERFLOW_ALLOWED)

get_thermal_limit_ex(self)

Thermal limit (kA) of each line on its extremity side (lv side for a trafo), grid2op numbering (powerlines then transformers)

get_thermal_limit_or(self)

Thermal limit (kA) of each line on its origin side (hv side for a trafo), grid2op numbering (powerlines then transformers)

lines_disconnected_this_step(self)

Lines (grid2op numbering) disconnected by the protections during the last step, all iterations together

set_max_line_time_step_overflow(self, ...)

Set, for each line (powerlines then transformers), the number of steps it can stay in overflow before the protections disconnect it (int32 vector)

set_thermal_limit_ex(self, thermal_limit_ex)

Set the thermal limits (kA) on the extremity side, one per line (powerlines then transformers).

set_thermal_limit_or(self, thermal_limit_or)

Set the thermal limits (kA) on the origin side, one per line (powerlines then transformers).

Attributes:

line_disconnected

Information on line / trafo disconnected

line_time_step_overflow

For how long each line has been on overflow

nb_iter

Number of 'iterations' used to perform the 'next_grid_state' (number of powerflow run) for the last call to 'next_grid_state' only

overflow_time

Total time spent to check the overflow, cumulated over an episode

powerflow_time

Total time spent to perform the powerflow (init DC + AC), cumulated over an episode

rho

Last computed 'rho' values.

total_time

Total time spent in the 'next_grid_state' function, cumulated over an episode

update_rho_time

Total time spent to update the value of rho, cumulated over an episode

v_init_ac

Complex voltage used to initialize the last AC powerflow (result of a DC powerflow)

v_init_dc

Complex voltage used to initialize the last DC powerflow

v_res_ac

Complex voltage at the end of the last powerflow

get_max_line_time_step_overflow(self: lightsim2grid.lightsim2grid_cpp.Protections) → Annotated[numpy.typing.NDArray[numpy.int32], '[m, 1]']

For each line, the number of steps it can stay in overflow: it is disconnected once its overflow counter exceeds this value (grid2op NB_TIMESTEP_OVERFLOW_ALLOWED)

get_thermal_limit_ex(self: lightsim2grid.lightsim2grid_cpp.Protections) → Annotated[numpy.typing.NDArray[numpy.float64], '[m, 1]']

Thermal limit (kA) of each line on its extremity side (lv side for a trafo), grid2op numbering (powerlines then transformers)

get_thermal_limit_or(self: lightsim2grid.lightsim2grid_cpp.Protections) → Annotated[numpy.typing.NDArray[numpy.float64], '[m, 1]']

Thermal limit (kA) of each line on its origin side (hv side for a trafo), grid2op numbering (powerlines then transformers)

property line_disconnected

Information on line / trafo disconnected

property line_time_step_overflow

For how long each line has been on overflow

lines_disconnected_this_step(self: lightsim2grid.lightsim2grid_cpp.Protections) → list[int]

Lines (grid2op numbering) disconnected by the protections during the last step, all iterations together

property nb_iter

Number of ‘iterations’ used to perform the ‘next_grid_state’ (number of powerflow run) for the last call to ‘next_grid_state’ only

property overflow_time

Total time spent to check the overflow, cumulated over an episode

property powerflow_time

Total time spent to perform the powerflow (init DC + AC), cumulated over an episode

property rho

Last computed ‘rho’ values.

set_max_line_time_step_overflow(self: lightsim2grid.lightsim2grid_cpp.Protections, max_line_time_step_overflow: Annotated[numpy.typing.NDArray[numpy.int32], '[m, 1]']) → None

Set, for each line (powerlines then transformers), the number of steps it can stay in overflow before the protections disconnect it (int32 vector)

set_thermal_limit_ex(self: lightsim2grid.lightsim2grid_cpp.Protections, thermal_limit_ex: Annotated[numpy.typing.NDArray[numpy.float64], '[m, 1]']) → None

Set the thermal limits (kA) on the extremity side, one per line (powerlines then transformers). rho is the max over both sides of current / thermal limit; a NaN or infinite limit leaves that side out (eg NaN on every extremity side for grid2op’s rho = a_or / limit).

set_thermal_limit_or(self: lightsim2grid.lightsim2grid_cpp.Protections, thermal_limit_or: Annotated[numpy.typing.NDArray[numpy.float64], '[m, 1]']) → None

Set the thermal limits (kA) on the origin side, one per line (powerlines then transformers). rho is the max over both sides of current / thermal limit; a NaN or infinite limit leaves that side out (eg NaN on every extremity side for grid2op’s rho = a_or / limit).

property total_time

Total time spent in the ‘next_grid_state’ function, cumulated over an episode

property update_rho_time

Total time spent to update the value of rho, cumulated over an episode

property v_init_ac

Complex voltage used to initialize the last AC powerflow (result of a DC powerflow)

property v_init_dc

Complex voltage used to initialize the last DC powerflow

property v_res_ac

Complex voltage at the end of the last powerflow

class lightsim2grid.lightEnv.TopoAction

Limited topological action used for the light environment, with grid2op semantics: add_element is grid2op set_bus (local busbar id: -1 disconnect, 0 nothing, 1..n_busbar_per_sub), set_line_status is grid2op set_line_status (-1, 0, +1). Line ids follow grid2op numbering (powerlines then transformers). check_validity(grid) validates the action and must be called before it can be applied (LightEnv.init_actions does it).

Methods:

add_element(self, el_type, el_id, local_bus_id)

grid2op set_bus on one element: add_element(ElementType el_type, int el_id, int local_bus_id) with local_bus_id -1 (disconnect), 0 (nothing) or 1..n_busbar_per_sub.

apply_to_gridmodel(self, grid)

Play the (checked) action on a grid: disconnect / reconnect / move its elements.

check_validity(self, grid)

Check the action against a grid (element exists, busbar exists, no contradiction) and resolve the busbars.

has_been_checked(self)

True if check_validity was called since the last modification

is_do_nothing(self)

True if the action does not modify anything

set_line_status(self, line_id, status)

grid2op set_line_status on one line (grid2op numbering): -1 disconnect, 0 nothing, +1 reconnect.

Attributes:

nb_set_bus

Number of (resolved) set_bus entries, after check_validity

nb_set_line_status

Number of (resolved) set_line_status entries, after check_validity

add_element(self: lightsim2grid.lightsim2grid_cpp.TopoAction, el_type: lightsim2grid.lightsim2grid_cpp.ElementType, el_id: SupportsInt | SupportsIndex, local_bus_id: SupportsInt | SupportsIndex) → None

grid2op set_bus on one element: add_element(ElementType el_type, int el_id, int local_bus_id) with local_bus_id -1 (disconnect), 0 (nothing) or 1..n_busbar_per_sub.

apply_to_gridmodel(self: lightsim2grid.lightsim2grid_cpp.TopoAction, grid: lightsim2grid.lightsim2grid_cpp.LSGrid) → None

Play the (checked) action on a grid: disconnect / reconnect / move its elements. The grid should be the one it was checked against, or a copy of it.

check_validity(self: lightsim2grid.lightsim2grid_cpp.TopoAction, grid: lightsim2grid.lightsim2grid_cpp.LSGrid) → None

Check the action against a grid (element exists, busbar exists, no contradiction) and resolve the busbars. Raises ValueError / IndexError on an invalid action.

has_been_checked(self: lightsim2grid.lightsim2grid_cpp.TopoAction) → bool

True if check_validity was called since the last modification

is_do_nothing(self: lightsim2grid.lightsim2grid_cpp.TopoAction) → bool

True if the action does not modify anything

property nb_set_bus

Number of (resolved) set_bus entries, after check_validity

property nb_set_line_status

Number of (resolved) set_line_status entries, after check_validity

set_line_status(self: lightsim2grid.lightsim2grid_cpp.TopoAction, line_id: SupportsInt | SupportsIndex, status: SupportsInt | SupportsIndex) → None

grid2op set_line_status on one line (grid2op numbering): -1 disconnect, 0 nothing, +1 reconnect.

lightsim2grid.lightEnv.topo_action_from_grid2op(action: BaseAction) → TopoAction[source]

Convert a grid2op action into a (not yet checked) TopoAction.

Only set_bus and set_line_status are modelled by the light environment. An action using anything else that affects the grid (change_bus, change_line_status, redispatch, curtail, storage, injections, shunts, detachment) raises a ValueError. Alarms and alerts are ignored, they do not affect the grid.

The values are copied as they are: the check that every element exists and every busbar exists is done against the grid by TopoAction.check_validity(), which LightEnv.init_actions() calls.